4Channels TENS EMS Sport Fitness Device For Physiotherapy
- Wide Selection
Quality Assurance
Global Reach
product description
Product Specification
Name | TENS&EMS DEVICE |
Mode | 15 |
Output Strength | 0-40 |
Channel | 4 channels |
Time | Up to 80mins |
Voltage | 3.7V/300mAh |
Channel | A/B independent channels |
Body weight | 130g |
Display mode | LCD display |
Size | 145*65*26mm |
Carton Package | 43.5*37.5*33.5CM 40Pcs/carton GW: 14kg
Device ,Manual ,4lead wires ,USB cable, 2bags electrode pads |
Product Feature
Back Light
A/B Independent channels
4output which can putput 100% power
Adjustable time up to 80minutes
15perating modes
Independent intensity for A and B channels
Easy to operate
Product Function
- Acting on nerve and ganglion segments, it can produce reflex effect and regulate autonomic nerve function.
2, Improve the tension of smooth muscle.
3, Exercise muscles, cause skeletal muscle contraction, prevent muscle atrophy.
4, Promote local tissue blood circulation and lymphatic reflex.
5, Pain-relief and promote healing after wound surgery.
Note
- Contraindications
Spasmodic paralysis, bleeding tendency, acute supper inflammation, skin lesions, local metal foreign bodies, pacemaker and its vicinity, etc. - The patient takes a comfortable position to relax the muscles, expose the treatment site, and find out the muscle points that need to be stimulated.
- Start the power supply and slowly adjust the current intensity to cause not too strong but obvious visible muscle contraction without obvious skin pain. (Too strong current will cause pain and muscle contraction, stiffness and trembling, contraction first strong and then weak, treatment still have a stiff and uncomfortable feeling.)
4, During the treatment , shall not be rude to remove the electrode, shall not be free to increase the current, so as not to be shocked. During the treatment, the patient should not arbitrarily move the body position, so as to avoid burns caused by shifting the position of the electrode liner and direct contact with the skin due to electrode shedding. There should be no pain and burning sensation under the electrode during the treatment. If there is pain during the treatment, the treatment should be stopped, and the electrode should be checked to see if the electrode slides off and touches the skin or if the electrode and liner are uneven, so that the current is concentrated at one point. If burns do not occur, they should be corrected. If burns have occurred, treatment should be interrupted and symptomatic treatment should be given.
- Before starting treatment, patients should be told how they should feel during treatment, and the treatment dose will increase slowly. During the treatment, patients with local sensory disorders and blood circulation disorders should be inspected frequently, especially to prevent burns.
- At the end of treatment, slowly adjust the current output back to zero, turn off the power, and remove the electrode and liner.
- After the treatment, tell the patient not to scratch the treatment site, and use toner if necessary.